<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>oil analysis lab Archives | Tesibis</title>
	<atom:link href="https://tesibis.com/tag/oil-analysis-lab/feed/" rel="self" type="application/rss+xml" />
	<link>https://tesibis.com/tag/oil-analysis-lab/</link>
	<description>Consulting &#38; Expert Testimony on Lubrication &#38; Oil Analysis</description>
	<lastBuildDate>Tue, 16 Dec 2025 19:46:04 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://tesibis.com/wp-content/themes/tesibis/assets/images/favicon/favicon-32x32.png</url>
	<title>oil analysis lab Archives | Tesibis</title>
	<link>https://tesibis.com/tag/oil-analysis-lab/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>How to Develop a &#8220;Win-Win&#8221; Relationship With Your Oil Analysis Lab</title>
		<link>https://tesibis.com/lubricant-analysis/2-how-to-develop-a-win-win-relationship-with-your-oil-analysis-lab/</link>
		
		<dc:creator><![CDATA[Jim Fitch]]></dc:creator>
		<pubDate>Tue, 16 Dec 2025 15:17:19 +0000</pubDate>
				<category><![CDATA[Lubricant Analysis]]></category>
		<category><![CDATA[data interpretation]]></category>
		<category><![CDATA[lab accreditation]]></category>
		<category><![CDATA[lab analysts]]></category>
		<category><![CDATA[lab instruments]]></category>
		<category><![CDATA[lab technicians]]></category>
		<category><![CDATA[oil analysis lab]]></category>
		<category><![CDATA[quality assurance]]></category>
		<category><![CDATA[test accuracy]]></category>
		<guid isPermaLink="false">https://tesibis.com/?p=567</guid>

					<description><![CDATA[<p>Turning an oil analysis program into a feisty profit center is well within reach of today's modern maintenance organizations. In fact, it is commonly achieved.</p>
<p>The post <a href="https://tesibis.com/lubricant-analysis/2-how-to-develop-a-win-win-relationship-with-your-oil-analysis-lab/">How to Develop a &#8220;Win-Win&#8221; Relationship With Your Oil Analysis Lab</a> appeared first on <a href="https://tesibis.com">Tesibis</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">By Jim Fitch<br>Booklet, Noria Publishing</p>



<figure class="wp-block-image size-full"><img fetchpriority="high" decoding="async" width="297" height="208" src="https://tesibis.com/wp-content/uploads/2025/12/image-24.png" alt="" class="wp-image-568"/></figure>



<p class="wp-block-paragraph">Turning an oil analysis program into a feisty profit center is well within reach of today&#8217;s modern maintenance organizations. In fact, it is commonly achieved. The strategy, perhaps, depends less on what the data is trying to communicate than the confidence the user assigns to the data. In fact, successful users of oil analysis have learned that achieving high confidence in oil analysis data is a team effort; the goals and responsibilities are shared equally between both the user and the laboratory. Such programs, when well-applied, result in a satisfying win-win business relationship.</p>



<p class="wp-block-paragraph">From the user&#8217;s perspective, there are many strategic elements to developing a positive working relationship with commercial oil analysis laboratories. When the end user has a basic understanding of the business needs of the laboratory and structures a program consistent with satisfying those needs, the underpinnings of a successful relationship exist. Likewise, the laboratory needs to provide the essential services needed to insure that the oil analysis program is sufficiently information-intensive and builds core value from the point of view of the user and his goals. These goals vary in emphasis from user to user but typically relate to subjects such as reduced lubricant consumption, root cause condition control, and incipient fault detection.</p>



<p class="wp-block-paragraph">Because a high percentage of today&#8217;s oil analysis users are setting up primary or auxiliary labs onsite, the lab-user relationship is changing and needs to be redefined. In such cases the service provider is internal and, being a stakeholder in the organization, would share many of the goals of reliability and cost reduction. However, unlike the commercial lab the onsite er corporate lab may not ~ motivated to achieve high sample volume, peak productivity, and near term profits. Consequently, the relationship must mold to the business environment.</p>



<div class="wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex">
<div class="wp-block-button is-style-tesibis-outline-blue-blue"><a class="wp-block-button__link wp-element-button" href="https://tesibis.com/pdf/articles/How-to-Develop-a-Win-Win-Lab-Relationship.pdf" target="_blank" rel="noreferrer noopener">Read the full booklet</a></div>
</div>
<p>The post <a href="https://tesibis.com/lubricant-analysis/2-how-to-develop-a-win-win-relationship-with-your-oil-analysis-lab/">How to Develop a &#8220;Win-Win&#8221; Relationship With Your Oil Analysis Lab</a> appeared first on <a href="https://tesibis.com">Tesibis</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Comparison of Particle Counts Between Eight Commercial Oil Analysis Laboratories</title>
		<link>https://tesibis.com/particle-contamination/3-comparison-of-particle-counts-between-eight-commercial-oil-analysis-laboratories/</link>
		
		<dc:creator><![CDATA[Jim Fitch]]></dc:creator>
		<pubDate>Tue, 16 Dec 2025 19:46:02 +0000</pubDate>
				<category><![CDATA[Particle Contamination]]></category>
		<category><![CDATA[oil analysis lab]]></category>
		<category><![CDATA[optical particle counting]]></category>
		<category><![CDATA[particle contamination]]></category>
		<category><![CDATA[particle count]]></category>
		<category><![CDATA[particle count accuracy]]></category>
		<category><![CDATA[particle counting]]></category>
		<guid isPermaLink="false">https://tesibis.com/?p=680</guid>

					<description><![CDATA[<p>The inclusion of particle counting in the periodic analysis of hydraulic and lubricating fluids has provided an important new advancement to machine diagnostics. With particle counting, machinery users can monitor the principal cause of failure, not just the symptoms, or results, of failure. The benefit, when particle levels are controlled, is extended machine life and reduced failure frequency. This is the objective of the growing practice of proactive maintenance.</p>
<p>The post <a href="https://tesibis.com/particle-contamination/3-comparison-of-particle-counts-between-eight-commercial-oil-analysis-laboratories/">Comparison of Particle Counts Between Eight Commercial Oil Analysis Laboratories</a> appeared first on <a href="https://tesibis.com">Tesibis</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">By Jim Fitch &amp; Holly J. Borden<br>Diagnetics Publishing</p>



<figure class="wp-block-image size-full"><img decoding="async" width="449" height="246" src="https://tesibis.com/wp-content/uploads/2025/12/image-52.png" alt="" class="wp-image-681" srcset="https://tesibis.com/wp-content/uploads/2025/12/image-52.png 449w, https://tesibis.com/wp-content/uploads/2025/12/image-52-300x164.png 300w" sizes="(max-width: 449px) 100vw, 449px" /></figure>



<p class="wp-block-paragraph">The inclusion of particle counting in the periodic analysis of hydraulic and lubricating fluids has provided an important new advancement to machine diagnostics. With particle counting, machinery users can monitor the principal cause of failure, not just the symptoms, or results, of failure. The benefit, when particle levels are controlled, is extended machine life and reduced failure frequency. This is the objective of the growing practice of proactive maintenance.</p>



<p class="wp-block-paragraph">Along with this important trend has come the practical questioning of particle counter accuracy. It is estimated that by the year 2000, as many as 50 million particle counts will be performed on fluid samples each year. Hence, a failure to do particle counting with reasonable accuracy could effectively undermine user confidence and erode this incredible rate of growth.</p>



<p class="wp-block-paragraph">While calibration techniques are available for most types of particle counters, the frequency and proper use of these techniques is not well understood. Likewise, it can be questioned whether the type of fluid and test particles (calibration fluid) used in calibration of particle counters is sufficiently close to field oils and field contaminants. Additionally, accuracy is also influenced by bottle cleanliness, fluid agitation, deaeration, dilution, dilution fluid cleanliness, and operator error.</p>



<div class="wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex">
<div class="wp-block-button is-style-tesibis-outline-blue-blue"><a class="wp-block-button__link wp-element-button" href="https://tesibis.com/pdf/articles/Comparison-of-Particle-Counts-Between-Eight-Commercial-Oil-Analysis-Laboratories.pdf" target="_blank" rel="noreferrer noopener">Read the full paper</a></div>
</div>
<p>The post <a href="https://tesibis.com/particle-contamination/3-comparison-of-particle-counts-between-eight-commercial-oil-analysis-laboratories/">Comparison of Particle Counts Between Eight Commercial Oil Analysis Laboratories</a> appeared first on <a href="https://tesibis.com">Tesibis</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
